  rev c dcqa 100 series up to 108 watts, quarter - brick dc/dc converters 11/14 /2013 wall industries, inc. ? 37 industrial drive , exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 1 of 7 size: 2.28 x 1.45 x 0.50 inches (57.9 x 36.8 x 12.7 mm) applications: ? automation ? telecom/datacom ? industry control systems ? icp ? measurement features ? soft start ? single outputs ? input under voltage protection ? high efficiency up to 93 % ? remote on/off con trol ? 2:1 wide input voltage ranges ? no minimum load required ? 2250vdc i/o basic insulation ? ? low stand - by power consumption ? industry standard quarter - brick package ? up to 108 watts maximum output power ? short circuit, over voltage, over loa d, & over temp. protection ? ul60950 - 1, en60950 - 1, and iec60950 - 1 safety approvals ? ce mark ed ? rohs & reach compliant ? optional heatsink s available (suffix ?hs?) ? description the dcqa 100 series of dc/dc power converters provides up to 108 watts of output power in a 2.28? x 1.45? x 0.5? industry standard quarter - brick package . this series has single output models with 2:1 wide input voltage ranges of 8.5 - 22vdc, 16.5 - 36vdc, and 33 - 75vdc. so me features include high efficiency up to 93 %, 2250vdc i/o basic insulation, and remote on/off control. these converters are also protected against input under voltage, short circuit, over voltage, over load, and over temperature conditions. all models are rohs compliant and have ul60950 - 1, en60950 - 1, and iec60950 - 1 safety approvals . several different options are available for this series including negative logic remote on/off, heatsinks, and thru - hole inserts. model selection table model number input vo ltage range output voltage output current output ripple & noise no load input current output power efficiency maximum capacitive load min load max load dcqa 100 - 12s33 12 vdc (8.5 - 22 vdc) 3.3 vdc 0ma 25 a 75mvp - p 5 0ma 82.5w 89 % 75 , 0 00f dcqa 100 - 12s05 5 vdc 0ma 1 8 a 75mvp - p 5 0ma 90w 90 % 36 , 000f dcqa 100 - 12s12 12 vdc 0ma 7.5 a 100mvp - p 5 0ma 90w 91 % 625 0f dcqa 100 - 12s15 15 vdc 0ma 6 a 100mvp - p 5 0ma 90w 91 % 40 00f dcqa 100 - 12s24 24 vdc 0ma 3.7 a 20 0mvp - p 5 0ma 88.8w 90 % 154 0f dcqa 100 - 12s30 30 vdc 0ma 3a 200mvp - p 50ma 90w 90% 1000f dcqa 100 - 12s48 48 vdc 0ma 1.8a 300mvp - p 50ma 86.4w 89% 380f dcqa 100 - 24s33 24 vdc (16.5 - 36 vdc) 3.3 vdc 0ma 25 a 75mvp - p 25 ma 82.5w 89 % 75 , 0 00f dcqa 100 - 24s05 5 vdc 0ma 18 a 75mvp - p 25 ma 90w 90 % 36 , 000f dcqa 100 - 2 4s12 12 vdc 0ma 7.5 a 100mvp - p 25 ma 90w 91 % 625 0f dcqa 100 - 24s15 15 vdc 0ma 6 a 100mvp - p 25 ma 90w 91 % 40 00f dcqa 100 - 24s24 24 vdc 0ma 3.7 a 20 0mvp - p 25 ma 88.8w 92 % 154 0f dcqa 100 - 24s30 30 vdc 0ma 3a 200mvp - p 25ma 90w 91 % 1000f dcqa 100 - 24s48 48 vdc 0 ma 1.8a 300mvp - p 25ma 86.4w 89% 380f dcqa 100 - 48s33 48 vdc (33 - 75 vdc) 3.3 vdc 0ma 25 a 75mvp - p 15 ma 82.5w 89 % 75 , 0 00f dcqa 100 - 48s05 5 vdc 0ma 21 a 75mvp - p 15 ma 105w 91 % 42 , 000f dcqa 100 - 48s12 12 vdc 0ma 9 a 100mvp - p 15 ma 108w 9 0 % 750 0f dcqa 100 - 48s 15 15 vdc 0ma 7 a 100mvp - p 15 ma 105w 91 % 46 00f dcqa 100 - 48s24 24 vdc 0ma 4.5 a 20 0mvp - p 15 ma 108w 93 % 187 0f dcqa 100 - 48s30 30 vdc 0ma 3.5a 200mvp - p 15ma 105w 92% 1160f dcqa 100 - 48s48 48 vdc 0ma 2.2a 300mvp - p 15ma 105.6w 91 % 460f notes 1. input sour ce impedance: the power modules will operate to specifications without external components, assuming that t he source voltage has very low impedance and reasonable input voltage regulation. highly inductive source impedances can affect the stability of the power mo dule. since real - world voltage sources have finite impedance, performance is improved by adding an external filter capacitor. we recommend using nippon chem i - con ky series, 100f/100v. 2. maximum output deviation is +10% inclusive of remote sense and trim. if remote sense is not being used , sense pins should connect to the output pins with the same polarity. 3 . the dcqa 100 series can only meet emi class a or class b with external components added. please contact factory for more information. 4 . a n external input filter capacitor is required if the module has to meet en61000 - 4 - 4, en61000 - 4 - 5. we re commend connecting two pieces of al uminum electrolytic capacitors ( nippon chemi - con ky series, 220f/100v ) . 5 . both positive logic and negative logic re mote on/off control is available. positive logic remote on/off comes standard; for negati ve logic remote on/off add the suffix ?r ? to the model number (ex: dcqa 100- 48s24r). 6 . optional heatsinks available. see page 5 for ordering details. 7 . m3 x 0.5 thr eaded- thru inserts come standard. for ?.126 thru - hole inserts add the suffix ?th ? to the model number (ex: dcqa 100- 4 8s24th). models with thru - hole inserts cannot be equipped with a heatsink. 8 . base - plate grounding: emi can be reduced when two screw bolts connected to shield plane . caution: this power module is not internally fused. an input line fuse must always be used.
rev c dcqa 100 series up to 108 watts, quarter - brick dc/dc converters 11/14 /2013 wall industries, inc. ? 37 industrial drive , exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 2 of 7 specifications: dcqa 100 series all specifications are based on 25c, nominal input voltage, and full load unless otherwise noted. we reserve the right to change specifications based on technological advances. specification test conditions min typ max unit input specifications input voltage range 12vdc nominal input models 8.5 12 22 vdc 24vdc nominal input models 16.5 24 36 48 vdc nominal input models 33 48 75 start - up voltage 12vdc nominal input models 9 vdc 24vdc nominal input models 18 48vdc nominal input models 36 shutdown voltage 12vdc nominal input models 7.3 7.7 8.1 vdc 24vdc nominal input models 15.5 15. 9 16.3 48vdc nominal input models 31.6 32 32.5 input surge voltage (1sec, max.) 12vdc nominal input models 30 vdc 24vdc nominal input models 50 48vdc nominal input models 100 input current no load see table input filter (see note 1) pi type output specifications output voltage see table voltage accuracy - 1.0 +1.0 % line regulation low line to high line at full load - 0.1 +0.1 % load regulation no load to full load 3.3v & 5v output models - 0.2 +0.2 % others - 0.1 +0.1 volt age adjustability maximum output deviation is inclusive of remote sense - 2 0 +10 % remote sense (see note 2) % of vo (nom) 10 % output power see table output current see table minimum load 0 % maximum capacitive load minimum input and constant resistive load see table ripple & noise (20mhz bw) measured with a 22 f/25v x7r mlcc 3.3v & 5v output models 75 mvp - p measured with a 22 f/25v x7r mlcc 12v & 15v output models 100 measured with a 4.7f/50v x7r mlcc 24v & 30v output models 200 measured with a 2.2f/10 0v x7r mlcc 48v output models 300 transient response recovery time 25% load step change 250 s start - up time constant resistive load power up 75 100 ms remote on/off 75 100 temperature coefficient - 0.02 +0.02 %/c protection short circuit protection continuous, automatic recovery over load protection % of rated iout; hiccup mode 110 140 % over voltage protection % of vo (nom); hiccup mode 115 130 % over temperature protection +110 c general specificatio ns efficiency nominal input voltage and full load see table switching frequency 270 30 0 330 khz isolation voltage 1 minute (basic insulation) input to output 2250 vdc input /output to base - plate 2250 vdc isolation resistance 500vdc 1 g
rev c dcqa 100 series up to 108 watts, quarter - brick dc/dc converters 11/14 /2013 wall industries, inc. ? 37 industrial drive , exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 3 of 7 specifications: dcqa 100 series all specifications are based on 25c, nominal input voltage, and full loa d unless otherwise noted. we reserve the right to change specifications based on technological advances. specification test conditions min typ max unit environmental specifications operating base - plate temperature - 40 +10 5 c storage temperature rang e - 55 +125 c thermal impedance (see note 6 ) vertical direction by natural c onvection (20lfm) without heatsink 9 c/w with 0.24? height heatsink 7.1 with 0.5? height heatsink 5.5 mounted on 2u iron base - plate 2.8 relative humidity 5 95 % rh thermal shock mil - std - 810f vibration mil - std - 810f mtbf mil - hdbk - 217f, full load 387,300 hours physical specifications weight 2.26oz (64 g) dimensions (l x w x h) 2.28x1.45x0.50 inch (57.9x36.8x12.7 mm) case material aluminum base - pla te with plastic case potting material silicon (ul94 - v0) safety & emc characteristics safety approvals iec60950 - 1, ul60950 - 1, en60950 - 1 emi (see note 3 ) en5503 2 class a, class b esd en61000 - 4 - 2 air 8kv contact 6kv perf. criteria a radiated immu nity en61000 - 4 - 3 20 v/m perf. criteria a fast transient (see note 4 ) en61000 - 4 - 4 2kv perf. criteria a surge (see note 4 ) en61000 - 4 - 5 en55024: 2 kv perf. criteria a conducted immunity en61000 - 4 - 6 10 vrms perf. criteria a power frequency mag netic field en61000 - 4 - 8 100a/m continuous; 1000a/m 1 sec perf. criteria a characteristic curves dcqa100 - 48s05 derating curve dcqa100 - 48s05 derating curve w/ 0.24? heatsink dcqa100 - 48s05 derating curve w/ 0.5? heatsink dcqa100 - 48s05 efficiency vs input voltage dcqa100 - 48s05 efficiency vs output load
rev c dcqa 100 series up to 108 watts, quarter - brick dc/dc converters 11/14 /2013 wall industries, inc. ? 37 industrial drive , exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 4 of 7 output voltage adjustment output is adjustable for 10% trim up or - 20% trim down of nominal output voltage by con necting an external resistor between the trim pin and either the +sense or - sense pins. with an external resistor between the trim and - sense pin, the output voltage set decreases. with an external resistor between the trim and + sense pin, the output vol tage set point increases. maximum output deviation is +10% inclusive of remote sense. the external trim resistor needs to be at least 1/8 of rated power the value of the external resistor can be obtained by the equations below. trim up equation trim down equation trim up 3.3v output models v (%) 1 2 3 4 5 6 7 8 9 10 vout (v) 3.333 3.366 3.399 3.432 3.465 3.498 3.531 3.564 3.597 3.630 ru (k?) 869.117 436.331 292.07 219.939 176.66 147.808 127.198 111.742 99 .72 90.103 5v output models v (%) ru (k?) v (%) ru (k?) v (%) ru (k?) v (%) ru (k?) v (%) ru (k?) v (%) ru (k?) trim down all outpu ts v (%) rd (k?) v (%) rd (k?) : ? 1 ?  ' k r d 22 . 10 % 511 : ? 1 ? ' '   ' '  k v r out u % % 22 . 10 511 % 225 . 1 % 100 11 . 5
rev c dcqa 100 series up to 108 watts, quarter - brick dc/dc converters 11/14 /2013 wall industries, inc. ? 37 industrial drive , exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 5 of 7 mechanical drawin g pin connection pin define diameter 1 - vin 0.04 inch 2 ctrl 0.04 inch 3 +vin 0.04 inch 4 - vout 0.06 inch 5 - sense 0.04 inch 6 trim 0.04 inch 7 +sense 0.04 inch 8 +vout 0.06 inch notes: 1. all dimensions in inch [mm] 2. tolerance: x.xx0.02 [x.x0.5] x.xxx0.01 [x.xxx0.25] 3. pin pitch tolerance: 0.01 [0.25] 4. pin dimension tolerance 0.004 [0.10] 5. the screw locked torque: max 3.5kgf - cm [0.34n - m] recommended pad layout notes: all di mensions in inch [mm] pad size (lead free recommended) through hole 1.2.3.5.6.7: ?0.051 [1.30] through hole 4.8: ?0.075 [1.90] through hole of mounting: ?0.126 [3.20] top view pad 1.2.3.5.6.7: ?0.064 [1.63] top view pad 4.8: ?0.094 [2.38] top view pad of m ounting: groove r0.065 [1.65] l0.157 [4.00] bottom view pad 1.2.3.5.6.7: ?0.102 [2.60] bottom view pad 8: ?0.150 [3.80] bottom view pad 4: ?0.130 [3.30] bottom view pad of mounting: groove r0.065 [1.65] l0252 [6.40]
rev c dcqa 100 series up to 108 watts, quarter - brick dc/dc converters 11/14 /2013 wall industries, inc. ? 37 industrial drive , exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 6 of 7 heatsink options horizon tal fin ori entation (suffix option: h ) 7g - 0029b - f horizontal fin ori entation (suffix option: h1) 7g - 0030b - f vertical fin ori entation (suffix option: h2 ) 7g - 0031b - f vertical fin o rientation (suffix option: h3) 7g - 0032b - f note: models with thru - hole inserts cannot be equipped with a heatsink all dimensions in inch [mm] tolerance: x.xx 0.02 [x.x 0.5] fuse consideration this power module is not internally fused. an input line fuse must always be u sed. this encapsulated power module can be used in a wide variety of applications, ranging from simple stand - alone operation to an integrated part of sophisticated power architecture. to maximum flexibility, internal fusing is not included; however, to ach ieve maximum safety protection, always use an input line fuse. the input line fuse suggestions are below: model fuse rating fuse type 12vdc nominal input models 20a fast - acting 24vdc nominal input models 10a fast - acting 48vdc nominal input models 6. 3a slow - blow the table is based on the information provided in this data sheet on inrush energy and maximum dc input current at low vin.
rev c dcqa 100 series up to 108 watts, quarter - brick dc/dc converters 11/14 /2013 wall industries, inc. ? 37 industrial drive , exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 7 of 7 thermal consideration this power module operates in a variety of thermal environments. however, s ufficient cooling should be provided to help ensure reliable operation of the unit. heat is removed by conduction, convection, and radiation to the surrounding environment. proper cooling can be verified by measuring the point in the figure below. the temp erature at this location should not exceed 105 o c. when operating, adequate cooling must be provided to maintain the test point temperature at or below 105 oc. although the maximum point, temperature of the power modules is 105oc, you can limit this temperat ure to a lower value for extremely high reliability. thermal test condition with vertical direction by national convection (20lfm) the iron base the heat 100: 100 watts 12: 8.5~22 vdc s: single output 33: 3. 3 vdc none: positive logic none: m3x0.5 threaded - thru inserts 24: 16.5~36 vdc 05: 5 vdc r: negative logic th: ?.126 thru - hole inserts (1) 48: 33~75 vdc 12: 12 vdc h: 0.24? horizontal heatsink 15: 15 vdc h1: 0.5? horizontal heatsink 24: 24 vdc h2: 0.24? vertical heatsink 30: 30 vdc h3: 0.5? vertical heatsink 48: 48 vdc (1) models with thru - hole inserts cannot be equipped with a heatsink. company information wall industries, inc. has created custom an d modified units for over 50 years. our in - house research and development engineers will provide a solution that exceeds your performance requirements on - time and on budget. our iso9001- 2008 certification is just one example of our commitment to producing a high quality, well - documented product for our customers. our past projects demonstrate our commitment to you, our customer. wall industries, inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. we will continue to provide ongoing support for your project above and beyond the design and production phases. give us a call today to discuss your future projects. contact wall industries for further information: phone: ? (60 3)778 - 2300 toll free: ? (888)59 7 - 9255 fax: ? (603)778 - 9797 e- mail: sales@wallindustries.com web: www.wallindustries.com address: 37 industrial drive exeter, nh 03833


▲Up To Search▲   

 
Price & Availability of DCQA100-24S30RH

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X